1. Gas Detectors & Monitors Items
  2. sku: 3775982662168713
  3. RAE SYSTEMS 048-5600-000

RAE SYSTEMS 048-5600-000 Qraeii Cradle Autorae Bump Unteste System Calibration

048-5600-000 Rae Systems Qraeii Cradle Autorae Bump And Calibration System Unteste

( Brand: Rae Systems ), ( Manufacturer Part Number: 048-5600-000 )

Review RAE SYSTEMS Qraeii Cradle Autorae Bump And Calibration System Unteste

Introducing the RAE Systems QRAE-II Cradle Autorae Bump Calibration Kit (Part Number: 048-5600-000), a vital accessory for ensuring the accuracy and reliability of your RAE Systems QRAE-II Gas Detection Module. This calibration kit is specifically designed for the QRAE-II series, providing a simple and efficient solution for conducting routine calibration checks.

The Autorae Bump Calibration Kit includes a calibration gas cylinder, a regulator, and a cradle. The cradle is the central component of the kit, serving as a secure and stable platform for the QRAE-II module during the calibration process. The cradle is engineered with a robust design, featuring non-slip surfaces to prevent any accidental movement or displacement of the module during calibration.

To begin the calibration process, attach the QRAE-II module to the cradle. The cradle is designed to accommodate the module securely, ensuring a snug fit and maintaining proper alignment with the sensor ports. Once the module is securely mounted, connect the calibration gas cylinder to the regulator, which in turn is connected to the sensor ports on the QRAE-II module.

The regulator allows for precise control of the calibration gas flow rate, ensuring a consistent and accurate calibration process. The Autorae Bump Calibration Kit includes a user-friendly interface for adjusting the flow rate, enabling users to easily calibrate their QRAE-II modules with confidence.

The calibration process involves exposing the sensors to the calibration gas for a specified duration, allowing the sensors to accurately measure the concentration of the gas. Once the calibration is complete, the QRAE-II module will display the new calibration data, allowing users to verify the accuracy of their gas detection system.

The RAE Systems QRAE-II Cradle Autorae Bump Calibration Kit is an essential accessory for any organization that relies on the QRAE-II series gas detection modules for ensuring workplace safety. By providing a simple, efficient, and accurate calibration solution, this kit helps ensure that your gas detection system remains reliable and effective, enabling you to protect your workers and maintain regulatory compliance.

The RAE Systems QRAE-II Cradle with AUTORAE Bump Calibration is a product designed for use with RAE Systems' gas detection instruments, specifically those utilizing the QRAE-II sensor. This cradle provides an automated way to perform calibration checks on the sensors, ensuring accurate and reliable readings. Here are some potential pros and cons of purchasing this product:

Pros:

1. Automated Calibration: The AUTORAE Bump Calibration feature automates the calibration process, reducing the need for manual calibration and potential human error.

2. Improved Accuracy: Regular calibration checks help ensure the gas detection instruments are providing accurate readings, which is crucial in environments where safety is paramount.

3. Time-Saving: The automated calibration process saves time compared to manual calibration methods.

4. Reduced Labor Costs: By automating the calibration process, organizations can reduce labor costs associated with manual calibration.

5. Integration with RAE Systems Instruments: The cradle is specifically designed for use with RAE Systems' QRAE-II sensors, ensuring compatibility and ease of use.

Cons:

1. Cost: The QRAE-II Cradle with AUTORAE Bump Calibration is a more expensive option compared to manual calibration methods or using other third-party calibration devices.

2. Limited Compatibility: The cradle is only compatible with RAE Systems' QRAE-II sensors, which may limit its usefulness for organizations using other brands or types of gas detection instruments.

3. Maintenance and Servicing: The cradle requires periodic maintenance and servicing, which may incur additional costs over time.

In conclusion, the RAE Systems QRAE-II Cradle with AUTORAE Bump Calibration offers several advantages, including automated calibration, improved accuracy, time-saving, and reduced labor costs. However, it comes with some disadvantages, such as cost, limited compatibility, and maintenance requirements.

Ultimately, the decision to purchase this product depends on an organization's specific needs and budget. If an organization frequently uses RAE Systems' QRAE-II sensors and values the benefits of automated calibration, the cradle may be a worthwhile investment. On the other hand, if the organization has limited budget or uses a variety of gas detection instruments, manual calibration methods or third-party calibration devices may be more cost-effective options.

part # 0485600000 price

  • $650.00

specifications detectoshould:

  • brand: Rae Systems
  • manufacturer part number: 048-5600-000

seller detectoshould:

  • # reviews: 72
  • rating: 98.0%

shipping detectoshould:

  • type: Calculated
  • transit: 4-12 Days
  • class: Expedited
  • cost: $13.38
  • service: USPS Priority Mail
  • carrier: USPS

payments detectoshould:

  • wallet: Paypal
  • other
  • credit card: Visa

offer detectoshould:

  • best offers: True
  • quantity: 1
  • options: Ship-to-home
  • started: February 9, 2026
  • availability: In Stock
  • sold: 0

returns detectoshould:

  • policy: No Returns

general detectoshould:

  • condition: Used
  • Test, Measurement Inspection > Test Meters Detectors > Gas Detectors Monitors
category: business & industrial > test, measurement inspection > test meters detectors > gas detectors monitors, sku: 3775982662168713,

Rae Systems 048-5600-000 Is Similar To:

detectoshould logo
1 offer $650.00 USD
  • Offer #1: $650.00 price + $14.46 delivery = $664.46* total. Part Number: P1. Model: QRAE II Cradle.+$14.46 shipping